E. coli Host Cell Protein ELISA Kit, G2 is for research use only, it should not be used in clinical diagnostic procedures. The kit is intended for the quantitative determination of residual host cell protein in Cell Culture Supernatants, Protein Purification Process, and End-Product expressed by E. coli expression systems.
Specifications Of EH-E0020-1 E. coli Host Cell Protein ELISA Kit, G2
Product's Information | |
Cat. NO. | EH-E0020-1 |
Products Name | E. coli Host Cell Protein ELISA Kit, G2 |
Species | E. coli |
Product Size | 96 Tests |
Concentration | 3.90625-250ng/ml |
Sensitivity | LOD: 1.95 ng/ml; LOQ: 3.9 ng/ml |
Principal | Sandwich ELISA |
Sample Volume | 100 ul |
Sample Type | The kit is intended for the quantitative determination of residual host cell protein in Cell Culture Supernatants, Protein Purification Process, and End-Product expressed by E. coli expression systems. |
Assay Time | 3 hours and 15 minutes |
Platform | Microplate Reader |
Conjugate | HRP |
Detection Method | Colorimetric |
Storage | 2-8°C |
Kit Components | ||
Reagents | Specification | Quantity |
Pre-Coated Microplate (Detachable) | 96 wells | 1 plate (Keep Sealed) |
Standard (Stock Solution) -500ug/ml | 50ul | 1 tube |
Detection antibody (100×) | 150ul | 1 tube |
TMB Substrates | 10ml | 1 vial (Avoid Light) |
Stop Solution | 10ml | 1 vial |
Wash Solution (100×) | 10ml | 1 vial |
Diluent Buffer (10×) | 10ml | 1 vial |
Plate Sealer | 4 pieces | |
Instruction Manual | 1 |
Principle of the Assay |
This ELISA kit is applied to the solid phase sandwich Enzyme-Linked Immunosorbent Assay. The microplate has been pre-coated with a capture antibody. The antigen to be measured and the HRP-conjugated detection antibody are then added to the microplate wells sequentially to form a capture antibody-antigen-detection antibody complex. After washing, the conjugates uninvolved in the reaction are removed, and then a TMB substrate solution is added to the wells to incubate. TMB substrate solution turns blue after the oxidation of HRP and finally turns yellow immediately after adding the stop solution. The color of the TMB substrate positively correlated with the antigen bound in the initial steps. Measure the absorbance (OD value) at 450nm using a microplate reader, and create a standard curve along with the corresponding concentrations. Then, by inputting the OD values of the samples into the standard curve equation, calculate the concentration of the target protein in the sample. |
Quality Control On EH-E0020-1 E. coli Host Cell Protein ELISA Kit, G2
CV | Intra Variation%: 7.3-13.1 | |
Inter Variation%: 8.1-11.5 | ||
Linearity | Diluent ratio | Range % |
1:2 | 97.7-102.6 | |
1:4 | 95.6-106.7 | |
1:8 | 90.3-105.9 | |
1:16 | 90.9-105.5 | |
1:32 | 94.0-106.5 | |
1:64 | 89.2-104 |