En
Email
  • bovine serum albumin elisa 1
  • bovine serum albumin elisa 1

BlueGene Biotech Human Endothelial Protein C Receptor ELISA kit (E01E0402)

E01E0402 Human Endothelial Protein C Receptor ELISA kit

The Human Endothelial Protein C Receptor ELISA kit can be used to identify samples from the human species. Endothelial Protein C Receptor can also be called PROCR, CCCA, CCD41, EPCR, protein C receptor, cluster of differentiation 201, activated protein C receptor, APC receptor.

Products

Specifications of Human Endothelial Protein C Receptor ELISA kit

Product Information

Cat. No.

E01E0402

Product Name

Human Endothelial Protein C Receptor ELISA kit

Species

Human

Product Size

48 Tests / 96 Tests

Concentration

25-500 ng/mL

Sensitivity

1.0 ng/ml

Principal

Competitive ELISA

Sample Volume

100 ul

Sample Type

Serum, plasma, cell culture supernatants, body fluid and tissue homogenate

Assay Time

90 minutes

Platform

Microplate Reader

Conjugate

HRP

Detection Method

Colorimetric

Storage

2-8°C


Kit Components

MATERIALS

SPECIFICATION

QUANTITY

MICROTITER PLATE

96 wells

stripwell

ENZYME CONJUGATE

6.0 mL

1 vial

STANDARD A (0.5mL)

0 ng/mL

1 vial

STANDARD B (0.5mL)

25 ng/mL

1 vial

STANDARD C (0.5mL)

50 ng/mL

1 vial

STANDARD D (0.5mL)

100 ng/mL

1 vial

STANDARD E (0.5mL)

250 ng/mL

1 vial

STANDARD F (0.5mL)

500 ng/mL

1 vial

SUBSTRATE A

6 mL

1 vial

SUBSTRATE B

6 mL

1 vial

STOP SOLUTION

6 mL

1 vial

WASH SOLUTION (100 x)

10 mL

1 vial

BALANCE SOLUTION

3 mL

1 vial


Principle of the Assay

EPCR ELISA kit uses an anti-EPCR antibody and an EPCR-HRP conjugate in a competitive enzyme immunoassay method. EPCR-HRP conjugate is incubated with the assay sample and buffer in a pre-coated plate for one hour. The wells are decanted and washed five times when the incubation period is over. The HRP enzyme substrate is then incubated in the wells. The result of the enzyme-substrate reaction is a complex that is blue in hue. The process is finally stopped by adding a stop solution, causing the solution to turn yellow. In a microplate reader, the color intensity is measured spectrophotometrically at 450 nm. Due to competition for the anti-EPCR antibody binding site between EPCR from samples and EPCR-HRP conjugate, the intensity of the color is inversely proportional to the concentration of EPCR. Since the number of sites is limited, as more sites are occupied by EPCR from the sample, fewer sites are left to bind EPCR-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The EPCR concentration in each sample is interpolated from this standard curve.


Quality Control on Human Endothelial Protein C Receptor ELISA kit

Coefficient of Variance

Intra Variation% <10%

Inter Variation% <12%

Recovery

95-102%

Linearity

Diluent Ratio

Range %

1:2

93-105

1:4

88-106

1:8

86-108

Specificity/Cross-reactivity

No significant cross-reactivity or interference between EPCR and analogues was observed.


BlueGene Biotech Product Show

Summary of the Assay Procedure for Human Endothelial Protein C Receptor ELISA kit

Summary of the Assay Procedure for Human Endothelial Protein C Receptor ELISA kit

Citations of Human Endothelial Protein C Receptor ELISA kit

E01E0402 has been referenced in the below publications:

Carbon monoxide-releasing molecule-2 suppresses thrombomodulin and endothelial protein C receptor expression of human umbilical vein endothelial cells induced by lipopolysaccharide in vitro.

Related Bluegene Biotech Products

Join us and become BlueGene's distributor, you will get a broad range of Life science research products and more than 12 years of experienced technical supports.