E02A0010 Rat Alpha Amylase ELISA kit
Rat Alpha Amylase ELISA kit is suitable for the detection of samples from Rat species. Alpha Amylase can also be called glycogenase, α amylase, endoamylase, Taka-amylase A, 1,4-α-D-glucan glucanohydrolase, AMY.
E02A0010 Rat Alpha Amylase ELISA kit
Rat Alpha Amylase ELISA kit is suitable for the detection of samples from Rat species. Alpha Amylase can also be called glycogenase, α amylase, endoamylase, Taka-amylase A, 1,4-α-D-glucan glucanohydrolase, AMY.
Product Information | |
Cat. No. | E02A0010 |
Product Name | Rat Alpha Amylase ELISA kit |
Species | Rat |
Product Size | 48 Tests / 96 Tests |
Concentration | 10-250ng/ml |
Sensitivity | 1.0 ng/mL |
Principal | Competitive ELISA |
Sample Volume | 100 ul |
Sample Type | Serum, plasma, cell culture supernatants, body fluid and tissue homogenate |
Assay Time | 90 minutes |
Platform | Microplate Reader |
Conjugate | HRP |
Detection Method | Colorimetric |
Storage | 2-8°C |
Kit Components | ||
MATERIALS | SPECIFICATION | QUANTITY |
MICROTITER PLATE | 96 wells | stripwell |
ENZYME CONJUGATE | 6.0 mL | 1 vial |
STANDARD A (0.5mL) | 0 ng/mL | 1 vial |
STANDARD B (0.5mL) | 10 ng/mL | 1 vial |
STANDARD C (0.5mL) | 25 ng/mL | 1 vial |
STANDARD D (0.5mL) | 50 ng/mL | 1 vial |
STANDARD E (0.5mL) | 100 ng/mL | 1 vial |
STANDARD F (0.5mL) | 250 ng/mL | 1 vial |
SUBSTRATE A | 6 mL | 1 vial |
SUBSTRATE B | 6 mL | 1 vial |
STOP SOLUTION | 6 mL | 1 vial |
WASH SOLUTION (100 x) | 10 mL | 1 vial |
BALANCE SOLUTION | 3 mL | 1 vial |
Principle of the Assay |
AMY ELISA kit applies the competitive enzyme immunoassay technique utilizing an anti-AMY antibody and an AMY-HRP conjugate. The assay sample and buffer are incubated together with AMY-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the AMY concentration since AMY from samples and AMY-HRP conjugate compete for the anti-AMY antibody binding site. Since the number of sites is limited, as more sites are occupied by AMY from the sample, fewer sites are left to bind AMY-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The AMY concentration in each sample is interpolated from this standard curve. |
Coefficient of Variance | Intra Variation% <10% | |
Inter Variation% <12% | ||
Recovery | 94-106% | |
Linearity | Diluent Ratio | Range % |
1:2 | 95-103 | |
1:4 | 93-108 | |
1:8 | 90-112 | |
Specificity/Cross-reactivity | No significant cross-reactivity or interference between AMY and analogues was observed. |
E02A0010 has been referenced in the below publications:
The protective effect and mechanism of the alanyl-glutamine dipeptide in the treatment of severe acute pancreatitis.
Related Bluegene Biotech Products
BlueGene Biotech News