E02A0018 Rat Adenosine Monophosphate ELISA kit
Rat Adenosine Monophosphate ELISA kit is suitable for the detection of samples from Rat species. Adenosine Triphosphate can also be called adenosine-5'-triphosphate, AMP.
E02A0018 Rat Adenosine Monophosphate ELISA kit
Rat Adenosine Monophosphate ELISA kit is suitable for the detection of samples from Rat species. Adenosine Triphosphate can also be called adenosine-5'-triphosphate, AMP.
Product Information | |
Cat. No. | E02A0018 |
Product Name | Rat Adenosine Monophosphate ELISA kit |
Species | Rat |
Product Size | 48 Tests / 96 Tests |
Concentration | 25-500 pmol/mL |
Sensitivity | 1.0 pmol/mL |
Principal | Competitive ELISA |
Sample Volume | 100 ul |
Sample Type | Serum, plasma, cell culture supernatants, body fluid and tissue homogenate |
Assay Time | 90 minutes |
Platform | Microplate Reader |
Conjugate | HRP |
Detection Method | Colorimetric |
Storage | 2-8°C |
Kit Components | ||
MATERIALS | SPECIFICATION | QUANTITY |
MICROTITER PLATE | 96 wells | stripwell |
ENZYME CONJUGATE | 6.0 mL | 1 vial |
STANDARD A (0.5mL) | 0 pmol/mL | 1 vial |
STANDARD B (0.5mL) | 25 pmol/mL | 1 vial |
STANDARD C (0.5mL) | 50 pmol/mL | 1 vial |
STANDARD D (0.5mL) | 100 pmol/mL | 1 vial |
STANDARD E (0.5mL) | 250 pmol/mL | 1 vial |
STANDARD F (0.5mL) | 500 pmol/mL | 1 vial |
SUBSTRATE A | 6 mL | 1 vial |
SUBSTRATE B | 6 mL | 1 vial |
STOP SOLUTION | 6 mL | 1 vial |
WASH SOLUTION (100 x) | 10 mL | 1 vial |
BALANCE SOLUTION | 3 mL | 1 vial |
Principle of the Assay |
AMP ELISA kit applies the competitive enzyme immunoassay technique utilizing an anti-AMP antibody and an AMP-HRP conjugate. The assay sample and buffer are incubated together with AMP-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the AMP concentration since AMP from samples and AMP-HRP conjugate compete for the anti-AMP antibody binding site. Since the number of sites is limited, as more sites are occupied by AMP from the sample, fewer sites are left to bind AMP-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The AMP concentration in each sample is interpolated from this standard curve. |
Coefficient of Variance | Intra Variation% <10% | |
Inter Variation% <12% | ||
Recovery | 93-106% | |
Linearity | Diluent Ratio | Range % |
1:2 | 95-103 | |
1:4 | 93-106 | |
1:8 | 91-110 | |
Specificity/Cross-reactivity | No significant cross-reactivity or interference between AMP and analogues was observed. |
E02A0018 has been referenced in the below publications:
Gualou Xiebai Decoction, a Traditional Chinese Medicine, Prevents Cardiac Reperfusion Injury in Hyperlipidemia Rats via Energy Modulation.
Related Bluegene Biotech Products