E03A0206 Mouse Angiotensin (1-7) ELISA kit
Mouse Angiotensin (1-7) ELISA kit is suitable for the detection of samples from mouse species. Angiotensin (1-7) can also be called ANG 1-7, ANG (1 7).
E03A0206 Mouse Angiotensin (1-7) ELISA kit
Mouse Angiotensin (1-7) ELISA kit is suitable for the detection of samples from mouse species. Angiotensin (1-7) can also be called ANG 1-7, ANG (1 7).
Product Information | |
Cat. No. | E03A0206 |
Product Name | Mouse Angiotensin (1-7) ELISA kit |
Species | Mouse |
Product Size | 48 Tests / 96 Tests |
Concentration | 50-1000 pg/mL |
Sensitivity | 1.0 pg/mL |
Principal | Competitive ELISA |
Sample Volume | 100 ul |
Sample Type | Serum, plasma, cell culture supernatants, body fluid and tissue homogenate |
Assay Time | 90 minutes |
Platform | Microplate Reader |
Conjugate | HRP |
Detection Method | Colorimetric |
Storage | 2-8°C |
Kit Components | ||
MATERIALS | SPECIFICATION | QUANTITY |
MICROTITER PLATE | 96 wells | stripwell |
ENZYME CONJUGATE | 6.0 mL | 1 vial |
STANDARD A (0.5mL) | 0 pg/mL | 1 vial |
STANDARD B (0.5mL) | 50 pg/mL | 1 vial |
STANDARD C (0.5mL) | 100 pg/mL | 1 vial |
STANDARD D (0.5mL) | 250 pg/mL | 1 vial |
STANDARD E (0.5mL) | 500 pg/mL | 1 vial |
STANDARD F (0.5mL) | 1000 pg/mL | 1 vial |
SUBSTRATE A | 6 mL | 1 vial |
SUBSTRATE B | 6 mL | 1 vial |
STOP SOLUTION | 6 mL | 1 vial |
WASH SOLUTION (100 x) | 10 mL | 1 vial |
BALANCE SOLUTION | 3 mL | 1 vial |
Principle of the Assay |
ANG (1-7) ELISA kit applies the competitive enzyme immunoassay technique utilizing an anti-ANG (1-7) antibody and an ANG (1-7)-HRP conjugate. The assay sample and buffer are incubated together with ANG (1-7)-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the ANG (1-7) concentration since ANG (1-7) from samples and ANG (1-7)-HRP conjugate compete for the anti-ANG (1-7) antibody binding site. Since the number of sites is limited, as more sites are occupied by ANG (1-7) from the sample, fewer sites are left to bind ANG (1-7)-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The ANG (1-7) concentration in each sample is interpolated from this standard curve. |
Coefficient of Variance | Intra Variation% <10% | |
Inter Variation% <12% | ||
Recovery | 94-109% | |
Linearity | Diluent Ratio | Range % |
1:2 | 97-113 | |
1:4 | 91-108 | |
1:8 | 96-102 | |
Specificity/Cross-reactivity | No significant cross-reactivity or interference between ANG (1-7) and analogues was observed. |
E03A0206 has been referenced in the below publications:
Ulinastatin activates the renin-angiotensin system to ameliorate the pathophysiology of severe acute pancreatitis.
Related Bluegene Biotech Products
BlueGene Biotech News