E07C0008 Porcine Cortisol ELISA kit
The Porcine Cortisol ELISA kit is suitable for detecting samples from porcine species. Cortisol can also be called CORT, Corticosrone.
E07C0008 Porcine Cortisol ELISA kit
The Porcine Cortisol ELISA kit is suitable for detecting samples from porcine species. Cortisol can also be called CORT, Corticosrone.
Product Information | |
Cat. No. | E07C0008 |
Product Name | Porcine Cortisol ELISA kit |
Species | Porcine |
Product Size | 48 Tests / 96 Tests |
Concentration | 50-1000 ng/mL |
Sensitivity | 1.0 ng/mL |
Principal | Competitive ELISA |
Sample Volume | 100 ul |
Sample Type | Serum, plasma, cell culture supernatants, body fluid and tissue homogenate |
Assay Time | 90 minutes |
Platform | Microplate Reader |
Conjugate | HRP |
Detection Method | Colorimetric |
Storage | 2-8°C |
Kit Components | ||
MATERIALS | SPECIFICATION | QUANTITY |
MICROTITER PLATE | 96 wells | stripwell |
ENZYME CONJUGATE | 6.0 mL | 1 vial |
STANDARD A (0.5mL) | 0 ng/mL | 1 vial |
STANDARD B (0.5mL) | 50 ng/mL | 1 vial |
STANDARD C (0.5mL) | 100 ng/mL | 1 vial |
STANDARD D (0.5mL) | 250 ng/mL | 1 vial |
STANDARD E (0.5mL) | 500 ng/mL | 1 vial |
STANDARD F (0.5mL) | 1000 ng/mL | 1 vial |
SUBSTRATE A | 6 mL | 1 vial |
SUBSTRATE B | 6 mL | 1 vial |
STOP SOLUTION | 6 mL | 1 vial |
WASH SOLUTION (100 x) | 10 mL | 1 vial |
BALANCE SOLUTION | 3 mL | 1 vial |
Principle of the Assay |
CORT ELISA kit applies the competitive enzyme immunoassay technique utilizing an anti-CORT antibody and an CORT-HRP conjugate. The assay sample and buffer are incubated together with CORT-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the CORT concentration since CORT from samples and CORT-HRP conjugate compete for the anti-CORT antibody binding site. Since the number of sites is limited, as more sites are occupied by CORT from the sample, fewer sites are left to bind CORT-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The CORT concentration in each sample is interpolated from this standard curve. |
Coefficient of Variance | Intra Variation% <10% | |
Inter Variation% <12% | ||
Recovery | 92-106% | |
Linearity | Diluent Ratio | Range % |
1:2 | 95-114 | |
1:4 | 92-108 | |
1:8 | 94-105 | |
Specificity/Cross-reactivity | No significant cross-reactivity or interference between CORT and analogues was observed. |