E02M0005 Rat Melatonin ELISA kit
The Rat Melatonin ELISA kit can be used to identify samples from the rat species. Melatonin can also be called MLT, MT.
E02M0005 Rat Melatonin ELISA kit
The Rat Melatonin ELISA kit can be used to identify samples from the rat species. Melatonin can also be called MLT, MT.
Product Information | |
Cat. No. | E02M0005 |
Product Name | Rat Melatonin ELISA kit |
Species | Rat |
Product Size | 48 Tests / 96 Tests |
Concentration | 50-1000 pg/ml |
Sensitivity | 1.0 pg/ml |
Principal | Competitive ELISA |
Sample Volume | 100 ul |
Sample Type | Serum, plasma, cell culture supernatants, body fluid and tissue homogenate |
Assay Time | 90 minutes |
Platform | Microplate Reader |
Conjugate | HRP |
Detection Method | Colorimetric |
Storage | 2-8°C |
Kit Components | ||
MATERIALS | SPECIFICATION | QUANTITY |
MICROTITER PLATE | 96 wells | stripwell |
ENZYME CONJUGATE | 6.0 mL | 1 vial |
STANDARD A (0.5mL) | 0 pg/mL | 1 vial |
STANDARD B (0.5mL) | 50 pg/mL | 1 vial |
STANDARD C (0.5mL) | 100 pg/mL | 1 vial |
STANDARD D (0.5mL) | 250 pg/mL | 1 vial |
STANDARD E (0.5mL) | 500 pg/mL | 1 vial |
STANDARD F (0.5mL) | 1000 pg/mL | 1 vial |
SUBSTRATE A | 6 mL | 1 vial |
SUBSTRATE B | 6 mL | 1 vial |
STOP SOLUTION | 6 mL | 1 vial |
WASH SOLUTION (100 x) | 10 mL | 1 vial |
BALANCE SOLUTION | 3 mL | 1 vial |
Principle of the Assay |
MLT ELISA kit uses an anti-MLT antibody and an MLT-HRP conjugate in a competitive enzyme immunoassay method. MLT-HRP conjugate is incubated with the assay sample and buffer in a pre-coated plate for one hour. The wells are decanted and washed five times when the incubation period is over. The HRP enzyme substrate is then incubated in the wells. The result of the enzyme-substrate reaction is a complex that is blue in hue. The process is finally stopped by adding a stop solution, causing the solution to turn yellow. In a microplate reader, the color intensity is measured spectrophotometrically at 450 nm. Due to competition for the anti-MLT antibody binding site between MLT from samples and MLT-HRP conjugate, the intensity of the color is inversely proportional to the concentration of MLT. Since the number of sites is limited, as more sites are occupied by MLT from the sample, fewer sites are left to bind MLT-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The MLT concentration in each sample is interpolated from this standard curve. |
Coefficient of Variance | Intra Variation% <10% | |
Inter Variation% <12% | ||
Recovery | 95-102% | |
Linearity | Diluent Ratio | Range % |
1:2 | 93-105 | |
1:4 | 88-106 | |
1:8 | 86-108 | |
Specificity/Cross-reactivity | No significant cross-reactivity or interference between MLT and analogues was observed. |
E02M0005 has been referenced in the below publications:
Observation of Electroacupuncture at Zusanli (St36) and Quchi (Li 11) on Two Peaks Blood Pressure and Serum Melatonin and Serotonin in Spontaneously Hypertensive Rats.
Serum melatonin is an alternative index of Parkinson's disease severity.
Effect of melatonin on visceral fat deposition, lipid metabolism and hepatic lipo-metabolic gene expression in male rats.
Related Bluegene Biotech Products