E03L0036 Mouse Leukotriene C4 ELISA kit
The Mouse Leukotriene C4 ELISA kit can be used to identify samples from the mouse species. Leukotriene C4 can also be called LT-C4, LTC4.
E03L0036 Mouse Leukotriene C4 ELISA kit
The Mouse Leukotriene C4 ELISA kit can be used to identify samples from the mouse species. Leukotriene C4 can also be called LT-C4, LTC4.
Product Information | |
Cat. No. | E03L0036 |
Product Name | Mouse Leukotriene C4 ELISA kit |
Species | Mouse |
Product Size | 48 Tests / 96 Tests |
Concentration | 50-1000pg/ml |
Sensitivity | 1.0pg/ml |
Principal | Sandwich ELISA |
Sample Volume | 50 ul |
Sample Type | Serum, plasma, cell culture supernatants, body fluid and tissue homogenate |
Assay Time | 90 minutes |
Platform | Microplate Reader |
Conjugate | HRP |
Detection Method | Colorimetric |
Storage | 2-8°C |
Kit Components | ||
MATERIALS | SPECIFICATION | QUANTITY |
MICROTITER PLATE | 96 wells | stripwell |
ENZYME CONJUGATE | 10 mL | 1 vial |
STANDARD A (0.5mL) | 0 pg/mL | 1 vial |
STANDARD B (0.5mL) | 50 pg/mL | 1 vial |
STANDARD C (0.5mL) | 100 pg/mL | 1 vial |
STANDARD D (0.5mL) | 250 pg/mL | 1 vial |
STANDARD E (0.5mL) | 500 pg/mL | 1 vial |
STANDARD F (0.5mL) | 1000 pg/mL | 1 vial |
SUBSTRATE A | 6 mL | 1 vial |
SUBSTRATE B | 6 mL | 1 vial |
STOP SOLUTION | 6 mL | 1 vial |
WASH SOLUTION (100 x) | 10 mL | 1 vial |
BALANCE SOLUTION | 3 mL | 1 vial |
Principle of the Assay |
LTC4 ELISA kit applies the quantitative sandwich enzyme immunoassay technique. The microtiter plate has been pre-coated with a monoclonal antibody specific for LTC4. Standards or samples are then added to the microtiter plate wells and LTC4 if present, will bind to the antibody pre-coated wells. In order to quantitatively determine the amount of LTC4 present in the sample, a standardized preparation of horseradish peroxidase (HRP)-conjugated polyclonal antibody, specific for LTC4 are added to each well to “sandwich” the LTC4 immobilized on the plate. The microtiter plate undergoes incubation, and then the wells are thoroughly washed to remove all unbound components. Next, substrate solutions are added to each well. The enzyme (HRP) and substrate are allowed to react over a short incubation period. Only those wells that contain LTC4 and enzyme-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The LTC4 concentration in each sample is interpolated from this standard curve. |
Coefficient of Variance | Intra Variation% <10% | |
Inter Variation% <12% | ||
Recovery | 95-102% | |
Linearity | Diluent Ratio | Range % |
1:2 | 93-105 | |
1:4 | 88-106 | |
1:8 | 86-108 | |
Specificity/Cross-reactivity | No significant cross-reactivity or interference between LTC4 and analogues was observed. |
E03L0036 has been referenced in the below publications:
Ameliorative effect of selective NLRP3 inflammasome inhibitor MCC950 in an ovalbumin-induced allergic rhinitis murine model.
Therapeutic effects of SKF-96365 on murine allergic rhinitis induced by OVA.
Downregulation of Orai1 expression in the airway alleviates murine allergic rhinitis.
Related Bluegene Biotech Products
BlueGene Biotech News