E03T0066 Mouse Toll Like Receptor 3 ELISA kit
The Mouse Toll Like Receptor 3 ELISA kit can be used to identify samples from the mouse species. Toll Like Receptor 3 can also be called TLR3, CD283, IIAE2, toll like receptor 3, IMD83.
E03T0066 Mouse Toll Like Receptor 3 ELISA kit
The Mouse Toll Like Receptor 3 ELISA kit can be used to identify samples from the mouse species. Toll Like Receptor 3 can also be called TLR3, CD283, IIAE2, toll like receptor 3, IMD83.
Product Information | |
Cat. No. | E03T0066 |
Product Name | Mouse Toll Like Receptor 3 ELISA kit |
Species | Mouse |
Product Size | 48 Tests / 96 Tests |
Concentration | 0.5-10ng/ml |
Sensitivity | 0.1ng/ml |
Principal | Competitive ELISA |
Sample Volume | 100 ul |
Sample Type | Serum, plasma, cell culture supernatants, body fluid and tissue homogenate |
Assay Time | 90 minutes |
Platform | Microplate Reader |
Conjugate | HRP |
Detection Method | Colorimetric |
Storage | 2-8°C |
Kit Components | ||
MATERIALS | SPECIFICATION | QUANTITY |
MICROTITER PLATE | 96 wells | stripwell |
ENZYME CONJUGATE | 6.0 mL | 1 vial |
STANDARD A (0.5mL) | 0 ng/ml | 1 vial |
STANDARD B (0.5mL) | 0.5ng/ml | 1 vial |
STANDARD C (0.5mL) | 1.0 ng/ml | 1 vial |
STANDARD D (0.5mL) | 2.5 ng/ml | 1 vial |
STANDARD E (0.5mL) | 5.0 ng/ml | 1 vial |
STANDARD F (0.5mL) | 10 ng/ml | 1 vial |
SUBSTRATE A | 6 mL | 1 vial |
SUBSTRATE B | 6 mL | 1 vial |
STOP SOLUTION | 6 mL | 1 vial |
WASH SOLUTION (100 x) | 10 mL | 1 vial |
BALANCE SOLUTION | 3 mL | 1 vial |
Principle of the Assay |
TLR3 ELISA kit applies the competitive enzyme immunoassay technique utilizing an anti-TLR3 antibody and a TLR3-HRP conjugate. The assay sample and buffer are incubated together with TLR3-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the TLR3 concentration since TLR3 from samples and TLR3-HRP conjugate compete for the anti-TLR3 antibody binding site. Since the number of sites is limited, as more sites are occupied by TLR3 from the sample, fewer sites are left to bind TLR3-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The TLR3 concentration in each sample is interpolated from this standard curve. |
Coefficient of Variance | Intra Variation% <10% | |
Inter Variation% <12% | ||
Recovery | 95-102% | |
Linearity | Diluent Ratio | Range % |
1:2 | 93-105 | |
1:4 | 88-106 | |
1:8 | 86-108 | |
Specificity/Cross-reactivity | No significant cross-reactivity or interference between TLR3 and analogues was observed. |
E03T0066 has been referenced in the below publications:
扶正解毒化瘀方及有效部位干预RSV肺炎小鼠的作用机制研究。